WTC-53 Series
Schedule A Consultation Today
*We respect your confidentiality and all information is protected.
Send


RTU
WTC-53 Series
Welletronics offers complete Ethernet connectivity solutions for our data acquisition needs. Data loggers are available with integrated Ethernet, as well as stand-alone Ethernet modules..
Features

It supports communication with the server (host computer software) via Ethernet

It collects and controls various instruments, sensors, and devices

It automatically gives an alarm in case of abnormalities to promptly detect potential accident hazards

The system has a flexible composition and can easily cope with project expansion

  • Description
  • Features
  • Technical Features
  • Downloads
  • FAQ
  • Inquiry

Technical Description


The WTC-5324 Ethernet Communicator is a network port-type universal controller with a modular and scalable measurement and control terminal that integrates data acquisition, logic control, and Ethernet-based remote communication into a single device. It can function independently as a compact data acquisition and automation controller or serve as the primary controller in extensive measurement and control systems.

The WTC-5324 connects to an Ethernet network using a 10Base-T/100Base-TX, full or half duplex, Ethernet interface. It has CS I/O and RS-485 ports for connecting  Welletronics instruments. A USB connection is provided for on-site configuration using Device Configuration Utility software.

WTC-5305 Expansion Peripherals

Expansion peripherals are used with data loggers to achieve many purposes, including the following: add additional channels, extend data communications networks, perform media conversions, read vibrating wire sensors, and build distributed measurement networks. 

WTC-7305 Input and Output and peripherals enable you to add channels to control other devices, such as activating external devices and increasing the number of analogue and digital output or input channels of a data logger. Some of these peripherals have built-in relays to control external devices, and other peripherals may require connected relays depending on what you want to control.




Product Picture


WTC-5324 (2).png


Features


It supports communication with the server (host computer software) via Ethernet.

  Ensure the stability and reliability of communication.

  Ensure the real-time performance and determinacy of data.

  Suitable for situations where high real-time data requirements exist or where a fiber optic network is already present on-site.

It collects and controls various instruments, sensors, and devices.

●  RS485: Collect output data from instruments such as flow meters and water quality meters.

●  AI: Collect signals from sensors such as pressure sensors and liquid level sensors.

●  DI: Collect the status of equipment operation, power supply, and the opening and closing of cabinet doors, etc.

●  DO: Support the control of equipment such as water pumps, sluice gates, and valves.

It automatically gives an alarm in case of abnormalities to promptly detect potential accident hazards.

●  The monitored data exceeds the limit.

●  Malfunctions occur in instruments and equipment.

The system has a flexible composition and can easily cope with project expansion.

  It can be cascaded with the Pingsheng IO expansion module DATA-7305 as required, and supports cascading up to 4 slave machines.

●  Communicate with the expansion module through the CAN port, achieving higher real-time data transmission.

●  With modular interface circuits, adding, expanding, or replacing slave machines will not affect the use of the master control logic.



Technical data

  • WorldwideTransmission Distance orArea

    World wide

  • Data Logger Interface

    40-pin peripheral port on CR1000 orCR3000

  • Ethernet

    10/100 Mbps, auto-detect10BaseT/100BaseTx, full/half duplex,lEEE 802.3. autoMDI/MDI-X

  • Power Source

    12 V from data logger 40-pin peripheralport

  • Power Consumption

    58 mA (typical) 3 mA (Ethernet off)

  • Operating TemperatureRange

    -40° to +70°C

  • Service Requirements

    Ethernet access

  • Dimensions

    10.2x6.4x2.8 cm (4.0x2.5x1.1 in.)

  • Weight

    66.62 g(2.35 oz)

  • Application of CouncilDirective(s)

    2004/108/EC ElectromagneticCompatibility Directive (EMC)

  • 2011/65/EU

    The Restriction of Hazardous SubstancesDirective (RoHS2)

  • Product Standard

    EN 61326-1:2013-Electrical Equipment formeasurement, control and laboratory use(EMC requirements -for use in industriallocations)

  • What core capabilities does the WTC-5324 offer for industrial automation?​

    • The WTC-5324 integrates ​data acquisition, logic control, and Ethernet-based remote communication​ into a single modular device, functioning as a standalone compact controller or a primary unit in large-scale systems. It supports 10Base-T/100Base-TX Ethernet, CS I/O, RS-485 ports, and USB for on-site configuration .
  • How do WTC-5305/WTC-7305 peripherals extend measurement systems?​

    • These peripherals ​add channels, enable media conversions, and build distributed networks, allowing control of external devices (e.g., via relays) and expansion of analog/digital I/O for data loggers in scenarios like sensor reading or network scaling
Customer service will contact you within 24 hours!  
Read more
Message *
Name *
Enter your Name
Email *
Enter your Email
Submit

Related Products

Contact us now
No. 116 Pancheng New Street, Pukou District, Nanjing
© 2019 Welletronics Fluid Technology Pte. Ltd.
contact@welletronics.com +86 (0)25-86618785
No. 116 Pancheng New Street, Pukou District, Nanjing
Contact Us Now
Name
Your Phone